The CO-NO2 transmitter is a wall mounted transmitter (IP65 rated) which detects CO and NO2 simultaneously  and manufactured by Evikon MCI Ltd, Estonia which specializes in gas detection systems. It is easy to use and it has two analog outputs settable at 4-20 mA or 0-10 V. The analog output scales are user adjustable, independent.The CO-NO2 transmitter has two SPST relays and acoustic alarm.

Another important feature is, it has a digital interface for RS485 connections working on Modbus RTU protocol. The operating conditions of this CO-NO2 Transmitter is -20 to +50 °C temperature and 15 to 90 % RH. It has a grey ABS plastic, wall mount, protection class IP65 enclosure. The dimensions of this CO-NO2 transmitter is H90 × W145× D55 mm. It has an IP65 secured remote sensor probe and the default length of this cable is 3.0 meters. The sensor heads are M25. 

The CO-NO2 transmitter is an ideal for underground parking, boiler houses and other confined spaces, where it is possible to accumulate potentially toxic concentration of carbon monoxide and nitrogen dioxide. Also this transmitter can be used in workshops and welding areas. Usually in workshops and welding areas, there are toxic and flammable gases and also there will be an oxygen deficiency. So the air quality should be monitored in these workshops and welding areas for the safety of the workers. This is an ideal for monitoring CO and NO2 simultaneously. 

Applications of CO-NO2 Transmitter, model no. VAC-E2660R-CO-NO2

  1. It is used in underground parking to monitor CO and NO2 simultaneously.
  2. It can be used in wastewater treatment areas.
  3. It is used in service garages for monitoring of CO and NO2.
  4. It is used in workshops and welding environments for the safety of the workers.
  5. It is used in ice skating arenas to check the air quality.

Features of CO-NO2 Transmitter, model no. VAC-E2660R-CO-NO2

  1. It can be monitored CO and NO2 simultaneously.
  2. It has a digital interface for RS485 connections working on Modbus RTU protocol.
  3. The sensor type of this CO-NO2 transmitter is an electrochemical.
  4. It has two analog outputs settable at 4-20 mA or 0-10 V.
  5. It has two SPST relays.
  6. It has a wall-mount IP65 protected housing.
  7. Self-diagnostics with full functionality check at start-up.
  8. The sensor heads are M25.
  9. It has an IP65 secured remote sensor probe and the default length of this cable is 3.0 meters.

Specifications of CO-NO2 Transmitter, model no. VAC-E2660R-CO-NO2 for underground parking, boiler houses, and workshops and welding areas

  1. VAC-E2660R-CO-NO2 can detect Carbon Monoxide CO and Nitrogen Dioxide NO2 simultaneously.
  2. The typical detection range for this CO-NO2 transmitter for underground parking is 0 to 1000 ppm CO and 0 to 20 ppm NO2.
  3. The CO and NO2 sensor type used is an electrochemical. 
  4. The dual gas transmitter model VAC-E2660R-CO-NO2 sampling method is diffusion.
  5. Maximum overload is 2000 ppm for CO and 100 ppm for NO2.
  6. The resolution is 1 ppm CO and 0.1 ppm NO2.
  7. The response time T90 is less than 30 s for CO and less than 40 s for NO2.
  8. The signal is updated every 1 second.
  9. The recalibration interval of this CO-NO2 transmitter for boiler houses is 6 months for both sensors.
  10. The sensor lifetime of CO sensor is more than 6 years and the sensor lifetime of NO2 sensor is more than 2 years.
  11. Self-diagnostics with full functionality check at start-up.
  12. The alarm setpoint can set at 25 ppm for CO and it releases at 20 ppm. And the alarm setpoint can set at 3 ppm for NO2 and it releases at 2.4 ppm.
  13. Warm-up time of this dual gas transmitter model VAC-E2660R-CO-NO2 is less than or equal to 10 minutes.
  14. The power supply of this dual gas transmitter model VAC-E2660R-CO-NO2 is 11 to 30 VDC or 90 to 265 VAC.
  15. The power consumption of this CO-NO2 transmitter for workshops and welding areas is less than 2 VA. 
  16. It has 2 SPST relay outputs (closing contact), 250 VAC / 30 VDC, 5 A max. 
  17. VAC-E2660R-CO-NO2 has a digital interface for RS485 connections working on Modbus RTU protocol.
  18. It has 2 universal analogue outputs settable at 4-20 mA or 0-10 V.
  19. The analog output scales are user adjustable, independent.
  20. It has a grey ABS plastic, wall mount, protection class IP65 enclosure. 
  21. The dimensions of this dual gas transmitter model VAC-E2660R-CO-NO2 is H90 × W145× D55 mm.
  22. VAC-E2660R-CO-NO2 has an IP65 secured remote sensor probe and the default length of the cable is 3.0 meters.
  23. It has M25 sensor heads. 
  24. Operating conditions of this dual gas transmitter model VAC-E2660R-CO-NO2 is -20 to +50 °C and 15 to 90 %RH.

We supply these CO-NO2 Transmitters in all Middle East countries including the United Arab Emirates, Kingdom of Saudi Arabia, Oman, Qatar, Bahrain, Iraq, Lebanon, Egypt, Jordan, Libya, Tunisia, etc.